Re: hp 41 synthetic programming Message #3 Posted by Thomas Klemm on 14 May 2011, 7:14 a.m., in response to message #1 by Sok-khieng Chum Hun
cf. HP-41C Synthetic Programming
As stated in the description of the program you can avoid synthetic programming:
Quote:
N.B: Synthetic registers M N O can be replaced by R01 R02 R03 but, in this case, delete line 31, replace line 02 with 0 STO 01 RDN in the following listing and choose bb > 03.
I recommend to give it a try, though.
Quote:
how to do this instruction : STO IND O
Only now I've realized that you might already have succeeded to enter STO O and you just have a problem with this specific command. Enter the following program and execute GTO . . (PACKING):
ENTER
STO IND 17
"1234567"
Now you go to the ENTER line and execute the byte-grabber, which will leave the sequence:
91: STO
F7: IND O
31: STO 01
32: STO 02
33: STO 03
34: STO 04
35: STO 05
36: STO 06
37: STO 07
HTH
Thomas
Edited: 14 May 2011, 7:51 a.m.
|