The Museum of HP Calculators

HP Forum Archive 14

[ Return to Index | Top of Index ]

HP-41: Data Transfer to PC via modem?
Message #1 Posted by Cococollector on 10 May 2004, 4:10 a.m.

Hi all,

while playing with the thought, how to exchange data between my 41 and my PC, I came up with the following:

Why build up this complicated chain of devices hard to get: 41 - HP-IL-module - IL-RS232-Interface - PC, when there's this 300-baud-modem (also hard to get, I know).

I don't yet know how it works, but shouldn't it be easier??? AND: my 41 would be part of today's electronically interconnected world :-)

I'm curious ...

Regards Klaus.

      
Re: HP-41: Data Transfer to PC via modem?
Message #2 Posted by Ángel Martin on 10 May 2004, 5:18 a.m.,
in response to message #1 by Cococollector

Klaus, if you use the Modem (also called Data Coupler) that's also an HP-IL device, thus you still need the same length chain:

HP-41 - HP-IL Module - Data Coupler - PC

The only thing you save is the PC IL-Card, however and as you said the IL-Data Coupler is hard to get. It also presents you with the software problem, what would you use to manage the communication?

Best, ÁM

            
Re: HP-41: Data Transfer to PC via modem?
Message #3 Posted by Cococollector on 10 May 2004, 5:25 a.m.,
in response to message #2 by Ángel Martin

Here's, where it's going to become interesting.

- What data is submitted over the coupler: IL? - Is software available that translates the ominous modem data into useful stuff? - Do I even have to interpret the data, if I have e.g. a 41-emulator running?

Got no clues so far, though I searched the web and literature thoroughly...

Klaus.

                  
Re: HP-41: Data Transfer to PC via modem?
Message #4 Posted by Claudio on 10 May 2004, 6:25 a.m.,
in response to message #3 by Cococollector

I think that you can use it like the RS232 converter. You must do two programs (one on the HP41 and one on the PC) with your protocol to transfer the data.

But I think that the true problem is the coupler itself. It only accept a phone (it's an acoustic coupler), so you can't use it like the RS232 converter. It hasn't electrical wire to connect to the PC.

Claudio

P.S.: remove the double "_nospam_" from my address! :-)

1234

                        
Re: HP-41: Data Transfer to PC via modem?
Message #5 Posted by Cococollector on 10 May 2004, 7:26 a.m.,
in response to message #4 by Claudio

That's the clue of it. Modems for PC are widely available, so I "only" need a way to find a means of transporting the data on the physical layer

                              
Re: HP-41: Data Transfer to PC via modem?
Message #6 Posted by Garth Wilson on 10 May 2004, 4:38 p.m.,
in response to message #5 by Cococollector

If you had a modem that worked with the HP-41, then you'd still need to either go through the phone service, or emulate the phone service with your own equipment that would provide the +48VDC and the pull-up resistors so the voltage drops into the area of 6V when you're off hook, and the 60VAC 20Hz ring signal. I've heard there are new computers without RS-232, but I think this is absurd. I wouldn't buy a computer without it.

      
Re: HP-41: Data Transfer to PC via modem?
Message #7 Posted by Vassilis Prevelakis on 11 May 2004, 11:06 p.m.,
in response to message #1 by Cococollector

You may want to have a look at a comms program for xfering files between the HP41 and the HP85. It was published in the PPC Journal (V10N2). Unfortunately you need the the XIO module on the 41, although I suspect that you can get the program to work (more or less) without it.

**vp

      
Re: HP-41: Data Transfer to PC via modem?
Message #8 Posted by Meindert Kuipers on 12 May 2004, 2:54 a.m.,
in response to message #1 by Cococollector

It will not be too long before it is possible to use USB to talk between the HP41 and a PC. The MLDL2000 is making good progress, only a few tests are remaining and then it is a matter of finishing the routing and making the PCB's!

Meindert

            
Re: HP-41 / PC Data Transfer
Message #9 Posted by Christoph Klug on 12 May 2004, 3:33 a.m.,
in response to message #8 by Meindert Kuipers

Dear HP41 / PC enthusiasts,

until MLDL2000 is comming use the "HP41-PC gateway & emulator" (article folder item 311).

Best regards from Germany - Christoph Klug


[ Return to Index | Top of Index ]

Go back to the main exhibit hall