WP34s 1.17 Build 874 possible SETTIM bug?
Message #1 Posted by BobVA on 17 May 2011, 10:29 p.m.

Hi: I noticed when using SETTIM that the input argument's seconds value seems to be ignored and replaced with some value between 10 and 14.

For example if I have 22.0400 on the stack, execute SETTIM then immediately press hTIME I get a value back of 22.0412 instead of an expected 22.0402 or something close to that.

Regards, Bob

      
Re: WP34s 1.17 Build 874 possible SETTIM bug?
Message #2 Posted by Tim Wessman on 17 May 2011, 10:36 p.m.,
in response to message #1 by BobVA

Wow! A command all for me. :-)

Tim W

            
Re: WP34s 1.17 Build 874 possible SETTIM bug?
Message #3 Posted by BobVA on 17 May 2011, 10:42 p.m.,
in response to message #2 by Tim Wessman

Oh man, I hope that's not changing your TV channels or something :-)

                  
Re: WP34s 1.17 Build 874 possible SETTIM bug? - Fixed!
Message #4 Posted by Marcus von Cube, Germany on 18 May 2011, 2:02 a.m.,
in response to message #3 by BobVA

I will check it. What happens, if you set the clock to something like 1.2345 ?

Edit: The seconds written to the RTC were definitely bogus. I fixed it in SVN for V.1.8. V1.17 will not be fixed.

Edited: 18 May 2011, 3:37 a.m.

                        
Re: WP34s 1.17 Build 874 possible SETTIM bug? - Fixed!
Message #5 Posted by BobVA on 18 May 2011, 10:01 p.m.,
in response to message #4 by Marcus von Cube, Germany

Just installed 1.18 - problem solved.

Thank you!

Bob

Edited: 18 May 2011, 10:04 p.m.

            
Re: WP34s 1.17 Build 874 possible SETTIM bug?
Message #6 Posted by John B. Smitherman on 18 May 2011, 11:58 p.m.,
in response to message #2 by Tim Wessman

Aren't you glad there's no KILLTIM command? ;-)

Regards,

John

                  
Re: WP34s 1.17 Build 874 possible SETTIM bug?
Message #7 Posted by Paul Dale on 19 May 2011, 12:02 a.m.,
in response to message #6 by John B. Smitherman

I can always add one :-)

- Pauli

                        
Re: WP34s 1.17 Build 874 possible SETTIM bug?
Message #8 Posted by Walter B on 19 May 2011, 1:58 a.m.,
in response to message #7 by Paul Dale

Come on, that was a peaceful project so far :-)

Walter

                        
Re: WP34s 1.17 Build 874 possible SETTIM bug?
Message #9 Posted by Tim Wessman on 19 May 2011, 10:26 a.m.,
in response to message #7 by Paul Dale

:-(

                              
Re: WP34s 1.17 Build 874 possible SETTIM bug?
Message #10 Posted by John B. Smitherman on 19 May 2011, 11:03 a.m.,
in response to message #9 by Tim Wessman

Other possibilities: PEEKTIM, POKETIM, PUTTIM, POPTIM, PUSHTIM, DIVIDETIM, ROTATETIM, FLOATTIM, MASKTIM, ABORTTIM...

Let's hope your wife doesn't execute REMOVETIM, SWAPTIM or REPLACETIM.

John