The Museum of HP Calculators

HP Forum Archive 19

[ Return to Index | Top of Index ]

HP-41CX Bug?
Message #1 Posted by Namir on 5 June 2009, 5:55 p.m.

Hi All,

Using my HP-41CX, I happened to execute CAT IND followed by the decimal and a stack register name (such as X or Y), expecting the command to use the value in the references stack register. Instead the calculator behaved like I entered CAT 0. Is this a know bug? Is it a bug at all? Am I missing something?

Namir

      
Re: HP-41CX Bug?
Message #2 Posted by Vladan Dugaric on 5 June 2009, 6:17 p.m.,
in response to message #1 by Namir

My HP-41CX exhibits the identical behaviour, V41 too. If I put 2 into register 00 for example, CAT IND 00 performs CAT 2. If I put 2 into a stack register (any of them), CAT IND ST X (or Y or Z or T) performs CAT 0. Strange.

Another interesting thing: i41CX+ does not allow CAT IND. When CAT is pressed, it comes out as CAT' and SHIFT key is ignored after that.

Edited: 5 June 2009, 6:22 p.m.

            
Re: HP-41CX Bug?
Message #3 Posted by Nigel Bamber on 6 June 2009, 10:30 a.m.,
in response to message #2 by Vladan Dugaric

Regarding the I41CX and CAT ' , you probably have CCD installed. Without CCD, it does allow you to enter CAT IND etc.

Nigel

                  
Re: HP-41CX Bug?
Message #4 Posted by Dan Grelinger on 6 June 2009, 4:54 p.m.,
in response to message #3 by Nigel Bamber

Nigel, I believe that you are wrong. I have an HP-41C (early, all bugs version), an HP-41CV 'fullnut', an HP-41CX 'fullnut' and an HP-41CX 'halfnut'.

All four instruments allow me to execute a CAT IND X, with no modules of any kind installed.

The result is the same for all of them, regardless of what resides in the X register. The HP-41 executes a CAT 3.

Dan

      
Re: HP-41CX Bug?
Message #5 Posted by Eric Smith on 5 June 2009, 8:22 p.m.,
in response to message #1 by Namir

Got any modules installed? ZenROM, CCD, and maybe other ROMs affect the way "partial key sequence" entry works.

            
Re: HP-41CX Bug?
Message #6 Posted by Namir on 6 June 2009, 6:33 a.m.,
in response to message #5 by Eric Smith

I have the IR printer module and an X-Mem module in my HP-41CX.

            
Re: HP-41CX Bug?
Message #7 Posted by Vladan Dugaric on 6 June 2009, 6:04 p.m.,
in response to message #5 by Eric Smith

You're right. After I removed CCD, Advantage, Math, and PPC modules, I now can execute CAT IND. However, as stated in a post below, the bug appears to be identical to the one on V41 and real HP-41.

      
Re: HP-41CX Bug?
Message #8 Posted by Dan Grelinger on 6 June 2009, 10:29 a.m.,
in response to message #1 by Namir

If memory serves me correctly, this 'bug' has been documented in at least one of the popular '3rd party' HP-41 books (Extend your HP-41?) It exists in all the HP-41 versions. It was omitted from almost all 'bug lists' because it was inconsequential. There was no real application for CAT IND (X-T), (CAT is not programmable) so the design and engineering effort was never expended by HP to 'fix' it.

Dan

            
Re: HP-41CX Bug?
Message #9 Posted by Namir on 7 June 2009, 4:44 p.m.,
in response to message #8 by Dan Grelinger

Thanks Dan. I just wanted to know if I was just "re-visiting" a previously known bug.

Namir

Edited: 7 June 2009, 4:44 p.m.


[ Return to Index | Top of Index ]

Go back to the main exhibit hall