The Museum of HP Calculators

HP Forum Archive 15

[ Return to Index | Top of Index ]

HP-41C battery contacts
Message #1 Posted by RicDng on 7 Oct 2005, 9:28 p.m.

Hi. I just got a HP-41C. I do not know if it works, and I do not want to buy N (E90) cells just to see if it works. I am planning to power it with some adaptor I will do, but I need to know if central battery contacts are connected to the internal circuits or just to each other.

Bye, Ricardo

      
Re: HP-41C battery contacts
Message #2 Posted by Randy on 7 Oct 2005, 10:03 p.m.,
in response to message #1 by RicDng

You can test with any good, clean 4.5 to 5.5 volt dc source. Power consumption is approximately 5 ma in the active state, it varies by model. The center two connections are only a jumper, there is no connection to the 41.

            
Re: HP-41C battery contacts
Message #3 Posted by RicDng on 7 Oct 2005, 10:13 p.m.,
in response to message #2 by Randy

Thank you, Randy

      
Re: HP-41C battery contacts
Message #4 Posted by don wallace on 7 Oct 2005, 11:15 p.m.,
in response to message #1 by RicDng

Hi Ric,

It's just possibly worth your while to current limit the power supply to few hundred millamps or so to test your 41C.

If there is anything along the lines of a short in the interconnections that way you will save the internal power supply regulator.

Second hand machines sure do arrive with some strange faults...

DW


[ Return to Index | Top of Index ]

Go back to the main exhibit hall